Sungrow SG string inverters

Inverter3 integration routes102 models on grid lists

Locallocal controlsungrow-inverter (SG Series Inverter), Sungrow Local· seen 2026-10-31
Grid✓✓✓✓✓✓✓fit in AT, BE, CZ, EE, NL, PL, SE · by the maker's document in 12 more countries · lists dated up to 2026-10-30

Local controlGrid listsModel codes

Local control with Home Assistant and evcc

checked 2026-10-31

Home Assistant
localread only2 integrations
evcc
localcontrol
Connection
Modbus TCP, Modbus RTU (RS485), Cloud API

Does Sungrow SG string inverters work locally with Home Assistant?

Yes, according to the public sources: the HACS integration “Sungrow Local” talks to it over the local network, read-only as far as we can tell; evcc supports it locally and lets evcc control it.

Firmware updates can open or close local access — check the integration's own page before you buy, and your installer before software changes export limits or charges a battery from the grid.

Evidence: integrations and templates

IntegrationSourceLinkRead or controlConnectionRepoSeen
Sungrow iSolarCloud KRoperUK/sungrow-hassHACS custom integrationcloudcontrol settable entities: number, selectCloud API (cloud_polling)★ 18 · 2026-10-262026-10-31
Sungrow Local SunnySkye/sungrow-localHACS custom integrationlocalread only sensors only (no settable entities found)Modbus TCP (local_polling)★ 0 · 2026-10-132026-10-31
sungrow-inverter (SG Series Inverter)evcc templatelocalcontrol evcc can curtail PV output (curtail)Modbus TCP, Modbus RTU (RS485)–2026-10-31

Grid-connection lists

The list is the authority; this is a cross-reference.

Is the Sungrow SG string inverters on an EU grid-connection list?

Yes — models of this family are on the lists of AT, BE, CZ, EE, NL, PL, SE (lists dated up to 2026-10-30, read 2026-10-31), every list read.

  • ATAustria — listed with restrictions “Nein” · 25 rows · Austrian TOR Erzeuger Typ A list dated 2026-10-30, read 2026-10-31✓
  • BEBelgium — listed · 63 rows · Belgian Synergrid C10/26 list dated 2026-10-30, read 2026-10-31✓
  • CZCzechia — listed · approved firmware MDSP: EMERALD-S_03011.01; LCD: EMERALD-S_01011.02 · 3 rows · Czech ČEZ Distribuce list dated 2026-08-21, read 2026-10-31✓
  • EEEstonia — listed · 49 rows · Estonian Elektrilevi inverter list (undated), read 2026-10-31✓
  • NLNetherlands — listed · 65 rows · Dutch Netbeheer Nederland type-A list dated 2026-10-30, read 2026-10-31✓
  • PLPoland — listed · firmware DSP_OPAL-C_V1_A · 34 rows · Polish PTPiREE WiPWC 1.3 list dated 2026-10-26, read 2026-10-31✓
  • SESweden — listed · firmware LCD_BERYL-S_V11_V01_A:MDSP_BERYL-S_V11_V01_A · 36 rows · Swedish Rikta Rätt inverter list dated 2026-10-23, read 2026-10-31✓

The other 36 countries: a inverter there

No model rows for these: they publish no usable list, or GridFit has not read it. Each gets one answer by the same rule as the grid view — the maker's own document first, then the country's type-A ceiling, then what the lists read say.

Fit by the maker's document (12)

SwitzerlandGermanysDenmarkSpainFinlandFrancesGreat BritainHungaryItalyNorthern IrelandNorwayPortugal

Sungrow's own document names these countries — the grid operator still decides at the application.

Product Certification and Country Code Overview (Europe) — the maker's released-countries table, version Version 3.5, 17.04.2025 (71 pages); seen 2026-10-31. Families “SGRT (three-phase string SG3.0–20RT)” (Austria absent from the SGRT list. Israel footnote: SG15RT-P2-V11 solely for Israel. The document's availability glyph per hardware version is an image GridFit could not read; the countries are those whose certification column is not NA — check the document for your hardware version); “SGRS (single-phase string SG2.0–6.0RS; SG2.0/2.5RS-S)” (Separate sub-table 'For SG8.0-10RS-V13 (big SGRS specially for Armenia and Spanish market)': Armenia EN50549-1 | Manual settings; Spain UNE217002, NTS SEPE 2.1, RD631,413,1699 | Spain | UFD. The document's availability glyph per hardware version is an image GridFit could not read; the countries are those whose certification column is not NA — check the document for your hardware version).

Accepted on other EU lists (22)

AlbaniaBosnia and HerzegovinaCyprusGreecesCroatiasIrelandIcelandLiechtensteinLithuaniaLuxembourgLatviaMoldovaMontenegroNorth MacedoniaMaltasRomaniaSerbiaSloveniaSlovakiaTürkiyeUkrainesKosovo?

On 7 EU lists (AT, BE, CZ, EE, NL, PL, SE): the maker has had the model certified and 7 grid operators accept it. Nothing is checked in these countries themselves: where there is no list the grid operator reads the maker's certificate for that country — ask the maker or installer for it; where a list exists that GridFit has not read, check the model there.

Not confirmed (2)

Bulgaria?Georgias

Whether a list or a rule applies is not confirmed yet.

s = from search results, ? = unverified; without a mark the country page was opened. The state per country comes from the EU+ grid-connection table; each country page says more.

Model codes on the lists

Matched to this family by model-code pattern (brand match alias / exact) — a pointer; confirm in the list. Hover a cell for the list's own words.

Model, as the list writes itATBECZEENLPLSEMPPTkWMatch
SG10.0RT-P2✓✓––alias
SG10KTL-M✓✓✓✓––alias
SG10RT✕✓✓✓✓––alias
SG10RT-P2✓✓––exact
SG1100UD✓✓––alias
SG110CX✕✓✓✓✓––alias
SG110CX - Premium V112 SG110CX✓––exact
SG110CX-P2✓✓––alias
SG110CX-P3✓✓✓––alias
SG12.0RT-P2✓✓––alias
SG125CX-P2✓✓✓✓✓✓––alias
SG125CX-P3✓✓✓✓✓––alias
SG125HV✕✓✓––exact
SG125HX✕✓✓✓––alias
SG12KTL-M✓✓✓✓––alias
SG12RT✕✓✓✓✓––alias
SG12RT-P2✓✓––exact
SG15.0RT-P2✓––alias
SG150CX✓✓✓✓✓––alias
SG15KTL-M✓✓✓––exact
SG15RT✕✓✓✓✓––alias
SG15RT-P2✓✓––exact
SG17.0RT-P2✓––alias
SG17RT✕✓✓✓✓––alias
SG17RT-P2✓✓––exact
SG2.0RS-S✓✓––exact
SG2.5RS-S✓✓––exact
SG20.0RT-P2✓––alias
SG20KTL-M✓✓✓––exact
SG20RT✕✓✓✓✓––alias
SG20RT-P2✓✓––exact
SG250HX✕✓✓✓––alias
SG250HX-20✓––alias
SG250HX-20 + Logger4000✓––alias
SG250HX-P2✓––alias
SG250HX-P2 + Logger4000✓––alias
SG250HX-P2-20✓––alias
SG250HX-P2-20 + Logger4000✓––alias
SG250HX-P2-21✓––alias
SG250HX-P2-21 + Logger4000✓––alias
SG25CX-P2✓✓✓✓––exact
SG25CX-P2 + Logger1000A-EU✓––alias
SG285HX✓––alias
SG285HX + Logger4000✓––alias
SG2K5-S✓✓––exact
SG3.0RS✓✓✓––alias
SG3.0RS-S✓✓––exact
SG3.0RT✓✓✓––alias
SG3.6RS✓✓✓––alias
SG305HX✓––alias
SG305HX + Logger4000✓––alias
SG30CX-P2✓✓✓✓––exact
SG30CX-P2 + Logger1000A-EU✓––alias
SG320HX✓––alias
SG320HX + Logger4000✓––alias
SG320HX-20✓––alias
SG320HX-20 + Logger4000✓––alias
SG333HX✓––alias
SG333HX + Logger4000✓––alias
SG33CX✕✓✓✓✓––alias
SG33CX - Premium V112 SG33CX✓––exact
SG33CX-P2✓✓✓✓✓✓––alias
SG33CX-P2 + Logger1000A-EU✓––alias
SG350HX✓✓✓✓––alias
SG350HX + Logger4000✓––alias
SG350HX-20✓✓––alias
SG350HX-20 + Logger4000✓––alias
SG36CX-P2✓✓✓✓––exact
SG36CX-P2 + Logger1000A-EU✓––alias
SG3K-D✓––alias
SG3K-S✓✓––exact
SG3K6-D✓✓✓––alias
SG4.0RS✓✓✓––alias
SG4.0RT✓✓✓––alias
SG40CX✕✓✓✓✓––alias
SG40CX - Premium V112 SG40CX✓––exact
SG40CX-P2✓✓✓✓✓––exact
SG40CX-P2 + Logger1000A-EU✓––alias
SG4K-D✓––alias
SG4K6-D✓✓✓––alias
SG5.0RS✓✓––exact
SG5.0RT✕✓✓✓✓––alias
SG5.0RT-P2✓✓✓✓––alias
SG50CX✕✓✓✓✓––alias
SG50CX - Premium V112 SG50CX✓––exact
SG50CX-P2✓✓✓✓✓✓––alias
SG50CX-P2 + Logger1000A-EU✓––alias
SG5K-D✓✓✓––alias
SG5KTL-MT✓✓✓✓––alias
SG6.0RS✓✓––exact
SG6.0RT✕✓✓✓✓––alias
SG6.0RT-P2✓✓✓✓––alias
SG60KTL✓✓––exact
SG6K-D✓✓✓––alias
SG6KTL-MT✓✓✓✓––alias
SG7.0RT✕✓✓✓✓––alias
SG7.0RT-P2✓✓✓✓––alias
SG75CX-P2✓✓✓✓––alias
SG8.0RT✕✓✓✓✓––alias
SG8.0RT-P2✓✓✓✓––alias
SG80CX-P3✓✓✓––alias
SG8KTL-M✓✓✓✓––alias

MPPT count and rated kW: no datasheet read for this family yet — “–” = not collected, never “none”.

How old the evidence is

Last 12 months. ◂ = older than the axis.

SourceDate
Sources read by GridFit2026-10-31
EE list dated2026-10-31
NL list dated2026-10-30
BE list dated2026-10-30
AT list dated2026-10-30
PL list dated2026-10-26
SE list dated2026-10-23
CZ list dated2026-08-21

Something wrong for your device? Fix the row