SAJ
5 families with a smart-home route, 5 local, 2 with control710 models on grid lists (AT, BE, EE, NL, PL, SE)
Local control with Home Assistant and evcc
5 families
| Product family | Class | Home Assistant | evcc | Local control | Grid lists | List models |
|---|---|---|---|---|---|---|
| H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | Hybrid inverter | local | not found | control | ✓✓✓✓✓ | 406 |
| R5 / R6 / Suntrio / Sununo string inverters | Inverter | local | not found | control | ✓✓✓✓✓✓ | 115 |
| H1 Series Hybrid Solar Inverter | Hybrid inverter | not found | local | read only | – | |
| H2 Series Hybrid Solar Inverter | Hybrid inverter | not found | local | read only | – | |
| R5 Series Solar Inverter | Inverter | not found | local | read only | – |
Grid-connection lists
710 models on 6 of 7 lists · 521 belong to a family above
The list is the authority; this is a cross-reference. Empty = no matching entry found, never “not approved”. A model name links to its page when it is in two or more lists, or to its family. All rows read 2026-10-31.
✓ fit: on the list✓ fit by the maker's document — the grid operator decides✕ not fit: refused, expired or not allowed nothing known — never “not approved”Hover or focus a cell for the list's own word, a condition or date, firmware and the row.
PV inverter
129
| Model | AT | BE | CZ | EE | NL | PL | SE | Match |
|---|---|---|---|---|---|---|---|---|
| C6-100K-T9R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| C6-100K-T9-40R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| C6-110K-T12R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| C6-110K-T12-40R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| C6-120K-T12R5 / R6 / Suntrio / Sununo string inverters | ✓ | alias | ||||||
| C6-125K-T12R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| C6-125K-T12-40R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| C6-75K-T6R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| C6-75K-T6-40R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| M2-1.8K-S4 | ✓ | exact | ||||||
| M2-2.25K-S4 | ✓ | exact | ||||||
| M2-2.2K-S4 | ✓ | exact | ||||||
| M2-2K-S4 | ✓ | exact | ||||||
| R5 Series 0 K-S1-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 1 K-S1-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 10K K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 12K K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 1K K-S1-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 2 K-S1-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 2K K-S1-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 3 K-S2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 3K K-S1-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 3K K-S2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 3K K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 4K K-S2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 4K K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 5K K-S2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 5K K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 6K K-S2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 6K K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 7K K-S2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 8K K-S2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 8K K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5 Series 9K K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | exact | ||||||
| R5-1.5K-S1R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-1.5K-S1-15 | ✓ | exact | ||||||
| R5-10K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| R5-10K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | alias | |||||
| R5-10K-T2-BR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-12K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| R5-12K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | alias | |||||
| R5-13K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| R5-15K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| R5-17K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| R5-1K-S1R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-1K-S1-15 | ✓ | exact | ||||||
| R5-2.5K-S1R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-2.5K-S1-15 | ✓ | exact | ||||||
| R5-20K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| R5-2K-S1R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-2K-S1-15 | ✓ | exact | ||||||
| R5-3.6K-S2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-3.6K-S2-15 | ✓ | exact | ||||||
| R5-3K-S1R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-3K-S1-15 | ✓ | exact | ||||||
| R5-3K-S2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-3K-S2-15 | ✓ | exact | ||||||
| R5-3K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| R5-3K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | alias | |||||
| R5-4K-S2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-4K-S2-15 | ✓ | exact | ||||||
| R5-4K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| R5-4K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | alias | |||||
| R5-5K-S2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-5K-S2-15 | ✓ | exact | ||||||
| R5-5K-S2-15-BR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-5K-S2-BR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-5K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| R5-5K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | alias | |||||
| R5-6K-S2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-6K-S2-15 | ✓ | exact | ||||||
| R5-6K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| R5-6K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | alias | |||||
| R5-7K-S2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-7K-S2-15 | ✓ | exact | ||||||
| R5-8K-S2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R5-8K-S2-15 | ✓ | exact | ||||||
| R5-8K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| R5-8K-T2-15R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | alias | |||||
| R5-9K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| R5-9K-T2-15 | ✓ | exact | ||||||
| R6-10K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R6-10K-T2-BR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R6-12K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R6-15K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R6-15K-T2-32R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| R6-17K-T2-32R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| R6-20K-T2-32R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| R6-22K-T2-32R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| R6-25K-T2-32R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| R6-25K-T2-32-BR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R6-25K-T3-32R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| R6-25K-T3-32-BR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R6-30K-T3-32R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| R6-30K-T3-32-BR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R6-33K-T3-32R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| R6-36K-T3-32R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| R6-36K-T4-32R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| R6-3K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R6-40K-T4-32R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| R6-4K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R6-50K-T4-32R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| R6-5K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R6-6K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| R6-8K-T2R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Suntrio Plus 10KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Suntrio Plus 12KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| Suntrio Plus 15KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| Suntrio Plus 17KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| Suntrio Plus 20KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| Suntrio Plus 25KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| Suntrio Plus 30KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| Suntrio Plus 33KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| Suntrio Plus 40KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| Suntrio Plus 4KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Suntrio Plus 50KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| Suntrio Plus 5KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Suntrio Plus 60KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | alias | ||||
| Suntrio Plus 6KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Suntrio Plus 8KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Sununo Plus 1.5KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Sununo Plus 1KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Sununo Plus 2.5KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Sununo Plus 2KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Sununo Plus 3KR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Sununo Plus 3K-MR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Sununo Plus 4K-MR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Sununo Plus 5K-MR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact | |||||
| Sununo Plus 6K-MR5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | exact |
Hybrid inverter
506
| Model | AT | BE | CZ | EE | NL | PL | SE | Match |
|---|---|---|---|---|---|---|---|---|
| AS2-10K-T-2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-10K-T-3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-10K-T-4H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-10K-T-5H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-10K-T-B-2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-10K-T-B-3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-10K-T-B-4H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-10K-T-B-5H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-10K-T-B-X (X=2, 3, 4, 5) | ✓ | alias | ||||||
| AS2-10K-T-X (X=2, 3, 4, 5) | ✓ | alias | ||||||
| AS2-5K-T-2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-5K-T-3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-5K-T-4H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-5K-T-5H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-5K-T-X (X=2, 3, 4, 5) | ✓ | alias | ||||||
| AS2-6K-T-2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-6K-T-3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-6K-T-4H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-6K-T-5H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-6K-T-X (X=2, 3, 4, 5) | ✓ | alias | ||||||
| AS2-8K-T-2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-8K-T-3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-8K-T-4H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-8K-T-5H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| AS2-8K-T-X (X=2, 3, 4, 5) | ✓ | alias | ||||||
| CH2-29.9K-T4 | ✓ | exact | ||||||
| CH2-30K-T4 | ✓ | exact | ||||||
| CH2-40K-T5 | ✓ | exact | ||||||
| CH2-49.9K-T6 | ✓ | exact | ||||||
| CH2-50K-T6 | ✓ | exact | ||||||
| CH2-63K-T6 | ✓ | exact | ||||||
| CH3-100K-T8-EU | ✓ | ✓ | alias | |||||
| CH3-110K-T8-EU | ✓ | ✓ | alias | |||||
| CH3-124.9K-T8-EU | ✓ | ✓ | alias | |||||
| CH3-125K-T8-EU | ✓ | ✓ | alias | |||||
| CH3-75K-T6-EU | ✓ | ✓ | alias | |||||
| CH3-80K-T6-EU | ✓ | ✓ | alias | |||||
| CH3-99.9K-T8-EU | ✓ | ✓ | alias | |||||
| CHS2-29.9K-T4-X | ✓ | ✓ | ✓ | ✓2 | ✓ | alias | ||
| CHS2-30K-T4-X | ✓ | ✓ | ✓ | ✓2 | ✓ | alias | ||
| CHS2-40K-T5-X | ✓ | ✓ | ✓2 | ✓ | alias | |||
| CHS2-50K-T6-X | ✓ | ✓ | ✓ | ✓2 | ✓ | alias | ||
| CHS2-63K-T6-X | ✓ | ✓ | ✓2 | ✓ | alias | |||
| EK60 H3-2.9K-LS2 | ✓ | exact | ||||||
| EK60 H3-3.6K-LS2 | ✓ | exact | ||||||
| EK60 H3-3K-LS2 | ✓ | exact | ||||||
| EK60 H3-4.6K-LS2 | ✓ | exact | ||||||
| EK60 H3-4K-LS2 | ✓ | exact | ||||||
| EK60 H3-5K-LS2 | ✓ | exact | ||||||
| EK60 H3-6K-LS2 | ✓ | exact | ||||||
| EK60 H3-6K-LS2-IE | ✓ | exact | ||||||
| EK70 HS5-10K-T3-12H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-14H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-16H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-18H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-21H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-24H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-25H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-27H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-28H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-30H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-35H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-36H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-40H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-42H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-45H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-50H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-54H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-6H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-7H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-10K-T3-9H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-12H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-12-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-14H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-14-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-15-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-16H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-16-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-18H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-18-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-21H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-21-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-24H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-24-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-25H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-25-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-27H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-27-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-28H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-28-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-30H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-30-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-35H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-35-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-36H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-36-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-40H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-40-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-42H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-42-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-45H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-45-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-50H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-50-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-54H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-54-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-6H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-6-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-7H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-7-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-9H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-12K-T3-9-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-12H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-14H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-16H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-18H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-21H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-24H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-25H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-27H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-28H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-30H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-35H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-36H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-40H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-42H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-45H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-50H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-54H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-6H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-7H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-15K-T3-9H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-12H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-14H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-16H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-18H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-21H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-24H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-25H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-27H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-28H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-30H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-35H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-36H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-40H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-42H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-45H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-50H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-54H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-6H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-7H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-20K-T3-9H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-5K-S3-12 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-14 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-15 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-16 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-18 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-21 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-24 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-25 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-27 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-28 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-30 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-35 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-36 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-40 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-42 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-45 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-50 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-54 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-6 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-7 | ✓ | exact | ||||||
| EK70 HS5-5K-S3-9 | ✓ | exact | ||||||
| EK70 HS5-8K-T3-12H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-14H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-16H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-18H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-21H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-24H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-25H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-27H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-28H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-30H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-35H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-36H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-40H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-42H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-45H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-50H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-54H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-6H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-7H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK70 HS5-8K-T3-9H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-12H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-14H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-16H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-18H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-21H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-24H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-25H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-27H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-28H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-30H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-35H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-36H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-40H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-42H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-45H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-50H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-54H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-6H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-7H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-10K-T3-9H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-12H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-12-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-14H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-14-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-15-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-16H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-16-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-18H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-18-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-21H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-21-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-24H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-24-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-25H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-25-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-27H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-27-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-28H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-28-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-30H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-30-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-35H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-35-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-36H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-36-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-40H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-40-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-42H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-42-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-45H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-45-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-50H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-50-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-54H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-54-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-6H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-6-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-7H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-7-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-9H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-12K-T3-9-IEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-12H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-14H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-16H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-18H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-21H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-24H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-25H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-27H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-28H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-30H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-35H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-36H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-40H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-42H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-45H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-50H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-54H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-6H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-7H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-15K-T3-9H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-12H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-14H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-16H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-18H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-21H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-24H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-25H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-27H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-28H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-30H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-35H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-36H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-40H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-42H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-45H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-50H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-54H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-6H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-7H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-20K-T3-9H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-5K-S3-12 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-14 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-15 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-16 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-18 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-21 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-24 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-25 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-27 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-28 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-30 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-35 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-36 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-40 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-42 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-45 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-50 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-54 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-6 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-7 | ✓ | exact | ||||||
| EK90 HS5-5K-S3-9 | ✓ | exact | ||||||
| EK90 HS5-8K-T3-12H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-14H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-16H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-18H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-21H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-24H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-25H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-27H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-28H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-30H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-35H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-36H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-40H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-42H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-45H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-50H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-54H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-6H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-7H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| EK90 HS5-8K-T3-9H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| H1-3.6K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| H1-3.6K-S2-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| H1-3K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| H1-3K-S2-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| H1-4.6K-LS2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| H1-4.6K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| H1-4.6K-S2-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| H1-4K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| H1-4K-S2-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| H1-5K-LS2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| H1-5K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| H1-5K-S2-15H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| H2-10K-T2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓2 | ✓ | ✓2 | ✓ | alias | |||
| H2-10K-T2-BH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| H2-10K-T3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓2 | ✓ | alias | |||
| H2-12K-T3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓2 | ✓ | alias | |||
| H2-15K-T2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓2 | ✓ | alias | |||
| H2-15K-T3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓2 | ✓ | alias | |||
| H2-20K-T2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓2 | ✓ | alias | |||
| H2-20K-T3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓2 | ✓ | alias | |||
| H2-25K-T3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓2 | ✓ | alias | |||
| H2-25K-T3-BEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓2 | ✓ | alias | |||
| H2-3.6K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| H2-30K-T3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓2 | ✓ | alias | |||
| H2-30K-T3-DEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓2 | ✓ | alias | |||
| H2-3K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| H2-4K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| H2-5K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| H2-5K-T2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓2 | ✓ | ✓2 | ✓ | alias | |||
| H2-6K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| H2-6K-T2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓2 | ✓ | ✓2 | ✓ | alias | |||
| H2-8K-T2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓2 | ✓ | ✓2 | ✓ | alias | |||
| HS2- 10K-T2-B-2 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2- 10K-T2-B-3 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2- 10K-T2-B-4 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2- 10K-T2-B-5 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2- 10K-T2-B-X WiFi (X=2, 3, 4, 5) | ✓ | alias | ||||||
| HS2-10K-T2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| HS2-10K-T2-2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-10K-T2-2 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-10K-T2-3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-10K-T2-3 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-10K-T2-4H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-10K-T2-4 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-10K-T2-5H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-10K-T2-5 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-10K-T2-BH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| HS2-10K-T2-B-2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-10K-T2-B-3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-10K-T2-B-4H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-10K-T2-B-5H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-10K-T2-B-X (X=2, 3, 4, 5) | ✓ | alias | ||||||
| HS2-10K-T2-XH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS2-10K-T2-X WiFi (X=2, 3, 4, 5) | ✓ | alias | ||||||
| HS2-3.6K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| HS2-3K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| HS2-4.6K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| HS2-4K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| HS2-5K-S2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| HS2-5K-S2-BH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| HS2-5K-T2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| HS2-5K-T2-2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-5K-T2-2 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-5K-T2-3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-5K-T2-3 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-5K-T2-4H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-5K-T2-4 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-5K-T2-5H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-5K-T2-5 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-5K-T2-XH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS2-5K-T2-X WiFi (X=2, 3, 4, 5) | ✓ | alias | ||||||
| HS2-6K-T2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| HS2-6K-T2-2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-6K-T2-2 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-6K-T2-3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-6K-T2-3 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-6K-T2-4H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-6K-T2-4 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-6K-T2-5H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-6K-T2-5 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-6K-T2-XH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS2-6K-T2-X WiFi (X=2, 3, 4, 5) | ✓ | alias | ||||||
| HS2-8K-T2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓2 | exact | |||||
| HS2-8K-T2-2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-8K-T2-2 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-8K-T2-3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-8K-T2-3 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-8K-T2-4H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-8K-T2-4 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-8K-T2-5H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-8K-T2-5 WiFiH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | alias | ||||||
| HS2-8K-T2-XH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS2-8K-T2-X WiFi (X=2, 3, 4, 5) | ✓ | alias | ||||||
| HS3-10K-T2-G-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-10K-T2-G-BX-BEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-10K-T2-G-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-10K-T2-G-PX-BEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-10K-T2-W-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-10K-T2-W-BX-BEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-10K-T2-W-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-10K-T2-W-PX-BEH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-12K-T2-G-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-12K-T2-G-BX-IE | ✓ | exact | ||||||
| HS3-12K-T2-G-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-12K-T2-G-PX-IE | ✓ | exact | ||||||
| HS3-12K-T2-W-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-12K-T2-W-BX-IE | ✓ | exact | ||||||
| HS3-12K-T2-W-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-12K-T2-W-PX-IE | ✓ | exact | ||||||
| HS3-3.6K-S2-G-BX | ✓ | exact | ||||||
| HS3-3.6K-S2-G-PX | ✓ | exact | ||||||
| HS3-3.6K-S2-W-BX | ✓ | exact | ||||||
| HS3-3.6K-S2-W-PX | ✓ | exact | ||||||
| HS3-3K-S2-G-BX | ✓ | exact | ||||||
| HS3-3K-S2-G-PX | ✓ | exact | ||||||
| HS3-3K-S2-W-BX | ✓ | exact | ||||||
| HS3-3K-S2-W-PX | ✓ | exact | ||||||
| HS3-3K-T2-G-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-3K-T2-G-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-3K-T2-W-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-3K-T2-W-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-4.6K-S2-G-BX | ✓ | exact | ||||||
| HS3-4.6K-S2-G-PX | ✓ | exact | ||||||
| HS3-4.6K-S2-W-BX | ✓ | exact | ||||||
| HS3-4.6K-S2-W-PX | ✓ | exact | ||||||
| HS3-4K-S2-G-BX | ✓ | exact | ||||||
| HS3-4K-S2-G-PX | ✓ | exact | ||||||
| HS3-4K-S2-W-BX | ✓ | exact | ||||||
| HS3-4K-S2-W-PX | ✓ | exact | ||||||
| HS3-4K-T2-G-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-4K-T2-G-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-4K-T2-W-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-4K-T2-W-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-5K-S2-G-BX | ✓ | exact | ||||||
| HS3-5K-S2-G-BX-BE | ✓ | exact | ||||||
| HS3-5K-S2-G-PX | ✓ | exact | ||||||
| HS3-5K-S2-G-PX-BE | ✓ | exact | ||||||
| HS3-5K-S2-W-BX | ✓ | exact | ||||||
| HS3-5K-S2-W-BX-BE | ✓ | exact | ||||||
| HS3-5K-S2-W-PX | ✓ | exact | ||||||
| HS3-5K-S2-W-PX-BE | ✓ | exact | ||||||
| HS3-5K-T2-G-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-5K-T2-G-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-5K-T2-W-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-5K-T2-W-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-6K-S2-G-BX | ✓ | exact | ||||||
| HS3-6K-S2-G-BX-IE | ✓ | exact | ||||||
| HS3-6K-S2-G-PX | ✓ | exact | ||||||
| HS3-6K-S2-G-PX-IE | ✓ | exact | ||||||
| HS3-6K-S2-W-BX | ✓ | exact | ||||||
| HS3-6K-S2-W-BX-IE | ✓ | exact | ||||||
| HS3-6K-S2-W-PX | ✓ | exact | ||||||
| HS3-6K-S2-W-PX-IE | ✓ | exact | ||||||
| HS3-6K-T2-G-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-6K-T2-G-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-6K-T2-W-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-6K-T2-W-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-8K-T2-G-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-8K-T2-G-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias | ||||
| HS3-8K-T2-W-BXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | alias | |||||
| HS3-8K-T2-W-PXH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | ✓ | alias |
Battery / AC inverter
73
| Model | AT | BE | CZ | EE | NL | PL | SE | Match |
|---|---|---|---|---|---|---|---|---|
| AS1-3KS-10.2H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS1-3KS-15.3H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS1-3KS-20.4H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS1-3KS-5.1H1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS2-10K-TH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS2-10K-T-BH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS2-3.6K-SH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS2-3K-SH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS2-4.6K-SH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS2-4K-SH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS2-5K-SH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS2-5K-S-BH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS2-5K-TH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS2-6K-TH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS2-8K-TH1 / H2 / HS2 / HS3 / HS5 / AS hybrids | ✓ | ✓ | exact | |||||
| AS3-10K-T-G-PX | ✓ | exact | ||||||
| AS3-10K-T-G-PX-BE | ✓ | exact | ||||||
| AS3-10K-T-W-PX | ✓ | exact | ||||||
| AS3-10K-T-W-PX-BE | ✓ | exact | ||||||
| AS3-12K-T-G-PX | ✓ | exact | ||||||
| AS3-12K-T-G-PX-IE | ✓ | exact | ||||||
| AS3-12K-T-W-PX | ✓ | exact | ||||||
| AS3-12K-T-W-PX-IE | ✓ | exact | ||||||
| AS3-3.6K-S-G-PX | ✓ | exact | ||||||
| AS3-3.6K-S-W-PX | ✓ | exact | ||||||
| AS3-3K-S-G-PX | ✓ | exact | ||||||
| AS3-3K-S-W-PX | ✓ | exact | ||||||
| AS3-3K-T-G-PX | ✓ | exact | ||||||
| AS3-3K-T-W-PX | ✓ | exact | ||||||
| AS3-4.6K-S-G-PX | ✓ | exact | ||||||
| AS3-4.6K-S-W-PX | ✓ | exact | ||||||
| AS3-4K-S-G-PX | ✓ | exact | ||||||
| AS3-4K-S-W-PX | ✓ | exact | ||||||
| AS3-4K-T-G-PX | ✓ | exact | ||||||
| AS3-4K-T-W-PX | ✓ | exact | ||||||
| AS3-5K-S-G-PX | ✓ | exact | ||||||
| AS3-5K-S-G-PX-BE | ✓ | exact | ||||||
| AS3-5K-S-W-PX | ✓ | exact | ||||||
| AS3-5K-S-W-PX-BE | ✓ | exact | ||||||
| AS3-5K-T-G-PX | ✓ | exact | ||||||
| AS3-5K-T-W-PX | ✓ | exact | ||||||
| AS3-6K-S-G-PX | ✓ | exact | ||||||
| AS3-6K-S-W-PX | ✓ | exact | ||||||
| AS3-6K-T-G-PX | ✓ | exact | ||||||
| AS3-6K-T-W-PX | ✓ | exact | ||||||
| AS3-8K-T-G-PX | ✓ | exact | ||||||
| AS3-8K-T-W-PX | ✓ | exact | ||||||
| CM2-125K-261R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| CM2-99.9K-261R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✓ | ✓ | alias | |||
| EK70 HS5- 10K T3-X; EK90 HS5- 10K T3-X (X=6/7/9/12/14/15/16/1 8/21/24/25/27/28/30/35 /36/40/42/45/50/54) | ✓ | alias | ||||||
| EK70 HS5- 12K T3-X- IE; EK90 HS5-12K T3-X-IE (X=6/7/9/12/14/15/16/1 8/21/24/25/27/28/30/35 /36/40/42/45/50/54) | ✓ | alias | ||||||
| EK70 HS5- 12K T3-X; EK90 HS5- 12K T3-X (X=6/7/9/12/14/15/16/1 8/21/24/25/27/28/30/35 /36/40/42/45/50/54) | ✓ | alias | ||||||
| EK70 HS5- 15K T3-X; EK90 HS5- 15K T3-X (X=6/7/9/12/14/15/16/1 8/21/24/25/27/28/30/35 /36/40/42/45/50/54) | ✓ | alias | ||||||
| EK70 HS5- 20K T3-X; EK90 HS5- 20K T3-X (X=6/7/9/12/14/15/16/1 8/21/24/25/27/28/30/35 /36/40/42/45/50/54) | ✓ | alias | ||||||
| EK70 HS5- 8K T3-X; EK90 HS5- 8K T3-X (X=6/7/9/12/14/15/16/1 8/21/24/25/27/28/30/35 /36/40/42/45/50/54) | ✓ | alias | ||||||
| HS3-10K-T2-W-BX-BE; HS3-10K-T2-G-BX-BE (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-10K-T2-W-BX; HS3-10K-T2-G-BX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-10K-T2-W-PX-BE; HS3-10K-T2-G-PX-BE (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-10K-T2-W-PX; HS3-10K-T2-G-PX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-12K-T2-W-BX-IE; HS3-12K-T2-G-BX-IE (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-12K-T2-W-BX; HS3-12K-T2-G-BX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-12K-T2-W-PX-IE; HS3-12K-T2-G-PX-IE (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-12K-T2-W-PX; HS3-12K-T2-G-PX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-3K-T2-W-BX; HS3-3K-T2-G-BX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-3K-T2-W-PX; HS3-3K-T2-G-PX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-4K-T2-W-BX; HS3-4K-T2-G-BX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-4K-T2-W-PX; HS3-4K-T2-G-PX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-5K-T2-W-BX; HS3-5K-T2-G-BX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-5K-T2-W-PX; HS3-5K-T2-G-PX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-6K-T2-W-BX; HS3-6K-T2-G-BX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-6K-T2-W-PX; HS3-6K-T2-G-PX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-8K-T2-W-BX; HS3-8K-T2-G-BX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias | ||||||
| HS3-8K-T2-W-PX; HS3-8K-T2-G-PX (X=1, 2, 3, 4, 5, 6, 7, 8) | ✓ | alias |
Plug-in solar / battery (≤ 800 VA)
2
| Model | AT | BE | CZ | EE | NL | PL | SE | Match |
|---|---|---|---|---|---|---|---|---|
| R5-0.7K-S1R5 / R6 / Suntrio / Sununo string inverters | ✓ | ✓ | ✕ | exact | ||||
| R5-0.7K-S1-15 | ✓ | ✕ | exact |
A small number after a symbol = the list has several rows for this model (variants, firmware versions). Something wrong? Fix a row.