Is the Lenercom LC-E2-1230T on the Austrian TOR Erzeuger Typ A list?
Yes — the Austrian TOR Erzeuger Typ A list lists it as “Ja - mit Einschränkung”; restriction applies from firmware: Software Version Identifier: 0; DSP Version: V1.03.30; ARM Version: V1.02.23; … (list dated 2026-10-30, checked 2026-10-31).
Steht der Lenercom LC-E2-1230T auf der österreichischen Wechselrichterliste (TOR Erzeuger Typ A)? Laut Liste vom 2026-10-30: „Ja - mit Einschränkung“.
Is the Lenercom LC-E2-1230T on the Belgian Synergrid C10/26 list?
Yes — the Belgian Synergrid C10/26 list lists it as “listed” (list dated 2026-10-30, checked 2026-10-31).
Is the Lenercom LC-E2-1230T on the Estonian Elektrilevi inverter list?
Yes — the Estonian Elektrilevi inverter list lists it as “listed” (the list is undated; checked 2026-10-31).
Is the Lenercom LC-E2-1230T on the Dutch Netbeheer Nederland type-A list?
Yes — the Dutch Netbeheer Nederland type-A list lists it as “listed” (list dated 2026-10-30, checked 2026-10-31).
Is the Lenercom LC-E2-1230T on the Swedish Rikta Rätt inverter list?
Yes — the Swedish Rikta Rätt inverter list lists it as “listed”; firmware: ARM: V1.02.08 DSP: V1.03.05 (list dated 2026-10-23, checked 2026-10-31).
The other 36 countries: a hybrid inverter there
No model rows for these: they publish no usable list, or GridFit has not read it. Each gets one answer by the same rule as the grid view — the maker's own document first, then the country's type-A ceiling, then what the lists read say.
- ○ Possibly fit: accepted on other EU lists (24)
Bosnia and Herzegovina?SwitzerlandCyprusGermanysDenmark?SpainFinlandFrancesGreat BritainGreecesCroatiasHungaryIrelandLiechtenstein?LithuaniaLuxembourgMoldova?Northern Ireland?NorwayPortugalRomania?SloveniasSlovakiaTürkiye?
On 5 EU lists (AT, BE, EE, NL, SE): the maker has had the model certified and 5 grid operators accept it. Nothing is checked in these countries themselves: where there is no list the grid operator reads the maker's certificate for that country — ask the maker or installer for it; where a list exists that GridFit has not read, check the model there.
- B Other procedure: over the type-A limit (1)
Italy
Above the type-A ceiling (11.08 kW in Italy): type B, a procedure of its own — conformity per installation, not a certificate per model.
- ? Unknown: not confirmed (11)
Albania?Bulgaria?Georgia?Iceland?Latvia?Montenegro?North Macedonia?Malta?Serbia?Ukraine?Kosovo?
Whether a list or a rule applies is not confirmed yet.
s = from search results, ? = unverified; without a mark the country page was opened. The state per country comes from the EU+ grid-connection table; each country page says more.
Rows are matched by maker and a normalised model code; the “as written” line shows exactly what each list says. Check the list itself, and your grid operator, before you install.