Hypontech HPT-25K

PV inverterin 4 of 7 listsno product family claims this code yet

Localnot found· seen 2026-10-31
Grid✓✓✓✓fit in BE, EE, NL, SE

Grid listsLocal controlAll Hypontech models

Grid-connection lists

The list is the authority; this is a cross-reference.

Is the Hypontech HPT-25K on the Belgian Synergrid C10/26 list?

Yes — the Belgian Synergrid C10/26 list lists it as “listed” (list dated 2026-10-30, checked 2026-10-31).

Is the Hypontech HPT-25K on the Estonian Elektrilevi inverter list?

Yes — the Estonian Elektrilevi inverter list lists it as “listed” (the list is undated; checked 2026-10-31).

Is the Hypontech HPT-25K on the Dutch Netbeheer Nederland type-A list?

Yes — the Dutch Netbeheer Nederland type-A list lists it as “listed” (list dated 2026-10-30, checked 2026-10-31).

Is the Hypontech HPT-25K on the Swedish Rikta Rätt inverter list?

Yes — the Swedish Rikta Rätt inverter list lists it as “listed”; firmware: V1.0.0.51 (list dated 2026-10-23, checked 2026-10-31).

  • ATAustria — Not found on the list · Austrian TOR Erzeuger Typ A list dated 2026-10-30, read 2026-10-31
  • BEBelgium — listed · Belgian Synergrid C10/26 list dated 2026-10-30, read 2026-10-31✓
  • CZCzechia — Not found on the list · Czech ČEZ Distribuce list dated 2026-08-21, read 2026-10-31
  • EEEstonia — listed · Estonian Elektrilevi inverter list (undated), read 2026-10-31✓
  • NLNetherlands — listed · Dutch Netbeheer Nederland type-A list dated 2026-10-30, read 2026-10-31✓
  • PLPoland — Not found on the list · Polish PTPiREE WiPWC 1.3 list dated 2026-10-26, read 2026-10-31
  • SESweden — listed · firmware V1.0.0.51 · Swedish Rikta Rätt inverter list dated 2026-10-23, read 2026-10-31✓

The other 36 countries: a inverter there

No model rows for these: they publish no usable list, or GridFit has not read it. Each gets one answer by the same rule as the grid view — the maker's own document first, then the country's type-A ceiling, then what the lists read say.

Possibly fit: accepted on other EU lists (33)

AlbaniaBosnia and HerzegovinaSwitzerlandCyprusGermanysDenmarkSpainFinlandFrancesGreat BritainGreecesCroatiasHungaryIrelandIcelandLiechtensteinLithuaniaLuxembourgLatviaMoldovaMontenegroNorth MacedoniaMaltasNorthern IrelandNorwayPortugalRomaniaSerbiaSloveniaSlovakiaTürkiyeUkrainesKosovo?

On 4 EU lists (BE, EE, NL, SE): the maker has had the model certified and 4 grid operators accept it. Nothing is checked in these countries themselves: where there is no list the grid operator reads the maker's certificate for that country — ask the maker or installer for it; where a list exists that GridFit has not read, check the model there.

Other procedure: over the type-A limit (1)

Italy

Above the type-A ceiling (11.08 kW in Italy): type B, a procedure of its own — conformity per installation, not a certificate per model.

Unknown: not confirmed (2)

Bulgaria?Georgias

Whether a list or a rule applies is not confirmed yet.

s = from search results, ? = unverified; without a mark the country page was opened. The state per country comes from the EU+ grid-connection table; each country page says more.

List by list

EE — Estonia

List
Inverterite nimekiri (Elektrilevi) (the list is undated)
Status
✓ listed
As written
Suzhou Hypontech Co, Ltd. · HPT-25K
Battery can be connected
no (the list's “Aku” column)
Match
alias · seen 2026-10-31

SE — Sweden

List
Rikta Rätt — växelriktare för solceller (dated 2026-10-23)
Status
✓ listed
As written
Hypontech · HPT-25K
Running no.
939
Firmware
V1.0.0.51
Date
2023-01-26 (reviewed)
Comment
EMC från tredje part saknas
Match
exact · seen 2026-10-31

Rows are matched by maker and a normalised model code; the “as written” line shows exactly what each list says. Check the list itself, and your grid operator, before you install.