Battery4 integration routes6 models on grid lists

Locallocal controlhuawei-sun2000-hybrid, Huawei Solar· seen 2026-10-31
Grid✓✓✓✓✓✓fit in AT, BE, EE, NL, PL, SE · lists dated up to 2026-10-30

Local controlGrid listsModel codes

Local control with Home Assistant and evcc

checked 2026-10-31

Home Assistant
localcontrol3 integrations
evcc
localcontrol
Connection
Modbus TCP, Modbus RTU (RS485), Cloud API

Does Huawei LUNA2000 batteries work locally with Home Assistant?

Yes, according to the public sources: the HACS integration “Huawei Solar” talks to it over the local network and exposes settable entities, not only sensors; evcc supports it locally and lets evcc control it.

Firmware updates can open or close local access — check the integration's own page before you buy, and your installer before software changes export limits or charges a battery from the grid.

Evidence: integrations and templates

IntegrationSourceLinkRead or controlConnectionRepoSeen
Huawei Solar wlcrs/huawei_solarHACS custom integrationlocalcontrol settable entities: number, select, switch, buttonModbus TCP, Modbus RTU (RS485) (local_polling)★ 939 · 2026-10-102026-10-31
FusionSolar tijsverkoyen/HomeAssistant-FusionSolarHACS custom integrationcloudread only sensors only (no settable entities found)Cloud API (cloud_polling)★ 241 · 2026-09-282026-10-31
FusionSolarPlus JortvanSchijndel/FusionSolarPlusHACS custom integrationcloudcontrol settable entities: switchCloud API (cloud_polling)★ 74 · 2026-10-142026-10-31
huawei-sun2000-hybridevcc templatelocalcontrol evcc controls battery charge/discharge (battery-control)Modbus TCP, Modbus RTU (RS485)–2026-10-31

Grid-connection lists

The list is the authority; this is a cross-reference.

Is the Huawei LUNA2000 batteries on an EU grid-connection list?

Yes — models of this family are on the lists of AT, BE, EE, NL, PL, SE (lists dated up to 2026-10-30, read 2026-10-31); the other 1 of the 7 lists read have no matching model, which is not a “no”.

  • ATAustria — listed “Ja” · Austrian TOR Erzeuger Typ A list dated 2026-10-30, read 2026-10-31✓
  • BEBelgium — listed · 2 rows · Belgian Synergrid C10/26 list dated 2026-10-30, read 2026-10-31✓
  • CZCzechia — Not found on the list · Czech ČEZ Distribuce list dated 2026-08-21, read 2026-10-31
  • EEEstonia — listed · 5 rows · Estonian Elektrilevi inverter list (undated), read 2026-10-31✓
  • NLNetherlands — listed · 2 rows · Dutch Netbeheer Nederland type-A list dated 2026-10-30, read 2026-10-31✓
  • PLPoland — listed · firmware PCS2000HA_V200R024 C10 · Polish PTPiREE WiPWC 1.3 list dated 2026-10-26, read 2026-10-31✓
  • SESweden — listed · firmware V200R023C00 · 2 rows · Swedish Rikta Rätt inverter list dated 2026-10-23, read 2026-10-31✓

The other 36 countries: a battery there

No model rows for these: they publish no usable list, or GridFit has not read it. Each gets one answer by the same rule as the grid view — the maker's own document first, then the country's type-A ceiling, then what the lists read say.

Accepted on other EU lists (16)

SwitzerlandCyprusGermanysDenmarkFinlandFrancesGreat BritainHungaryIrelandItalyLiechtensteinLithuaniaLuxembourgNorthern Ireland?NorwayRomania

On 6 EU lists (AT, BE, EE, NL, PL, SE): the maker has had the model certified and 6 grid operators accept it. Nothing is checked in these countries themselves: where there is no list the grid operator reads the maker's certificate for that country — ask the maker or installer for it; where a list exists that GridFit has not read, check the model there.

Over the type-A limit: type B, a procedure of its own (1)

Spain

Above the type-A ceiling (100 kW in Spain): type B, a procedure of its own — conformity per installation, not a certificate per model.

Not confirmed (19)

AlbaniasBosnia and Herzegovina?Bulgaria?Georgia?GreecesCroatia?Iceland?Latvia?Moldova?Montenegro?North Macedonia?Malta?Portugal?Serbia?Slovenia?Slovakia?TürkiyeUkraine?Kosovo?

Whether a list or a rule applies is not confirmed yet.

s = from search results, ? = unverified; without a mark the country page was opened. The state per country comes from the EU+ grid-connection table; each country page says more.

Model codes on the lists

Matched to this family by model-code pattern (brand match alias / exact) — a pointer; confirm in the list. Hover a cell for the list's own words.

Model, as the list writes itATBECZEENLPLSEMPPTkWMatch
LUNA2000-100KTL-M1✓✓✓2none–alias
LUNA2000-200KTL-2H0 ( ühendamine keskpingevõrku läbi trafo )✓none–alias
LUNA2000-200KTL-H0 ( ühendamine keskpingevõrku läbi trafo )✓none–alias
LUNA2000-200KTL-H1✓✓2none–exact
LUNA2000-200KWH-2H1 ( ühendamine keskpingevõrku läbi trafo )✓none–alias
LUNA2000-213KTL-H0✓✓✓none–alias

A battery / AC inverter has no MPPT (no PV input); rated kW not collected yet.

How old the evidence is

Last 12 months. ◂ = older than the axis.

SourceDate
Sources read by GridFit2026-10-31
EE list dated2026-10-31
NL list dated2026-10-30
BE list dated2026-10-30
AT list dated2026-10-30
PL list dated2026-10-26
SE list dated2026-10-23

Something wrong for your device? Fix the row