GridFit

Fimer PVS-12.5-TL-SX

PV inverterin 3 of 7 listsno product family claims this code yet

Localbrand route, model unconfirmedAurora ABB PowerOne Solar PV, PVI inverters via VSN300/VSN700· seen 2026-10-31
Grid✓✓✓fit in BE, NL, SE

Grid listsLocal controlAll Fimer models

Grid-connection lists

The list is the authority; this is a cross-reference.

Is the Fimer PVS-12.5-TL-SX on the Belgian Synergrid C10/26 list?

Yes — the Belgian Synergrid C10/26 list lists it as “listed” (list dated 2026-10-30, checked 2026-10-31).

Is the Fimer PVS-12.5-TL-SX on the Dutch Netbeheer Nederland type-A list?

Yes — the Dutch Netbeheer Nederland type-A list lists it as “listed” (list dated 2026-10-30, checked 2026-10-31).

Is the Fimer PVS-12.5-TL-SX on the Swedish Rikta Rätt inverter list?

Yes — the Swedish Rikta Rätt inverter list lists it as “listed”; firmware: ?2121A (SWEDEN) (list dated 2026-10-23, checked 2026-10-31).

  • ATAustria — Not found on the list · Austrian TOR Erzeuger Typ A list dated 2026-10-30, read 2026-10-31
  • BEBelgium — listed · Belgian Synergrid C10/26 list dated 2026-10-30, read 2026-10-31✓
  • CZCzechia — Not found on the list · Czech ČEZ Distribuce list dated 2026-08-21, read 2026-10-31
  • EEEstonia — Not found on the list · Estonian Elektrilevi inverter list (undated), read 2026-10-31
  • NLNetherlands — listed · Dutch Netbeheer Nederland type-A list dated 2026-10-30, read 2026-10-31✓
  • PLPoland — Not found on the list · Polish PTPiREE WiPWC 1.3 list dated 2026-10-26, read 2026-10-31
  • SESweden — listed · firmware ?2121A (SWEDEN) · Swedish Rikta Rätt inverter list dated 2026-10-23, read 2026-10-31✓

The other 36 countries: a inverter there

No model rows for these: they publish no usable list, or GridFit has not read it. Each gets one answer by the same rule as the grid view — the maker's own document first, then the country's type-A ceiling, then what the lists read say.

Possibly fit: accepted on other EU lists (33)

AlbaniaBosnia and HerzegovinaSwitzerlandCyprusGermanysDenmarkSpainFinlandFrancesGreat BritainGreecesCroatiasHungaryIrelandIcelandLiechtensteinLithuaniaLuxembourgLatviaMoldovaMontenegroNorth MacedoniaMaltasNorthern IrelandNorwayPortugalRomaniaSerbiaSloveniaSlovakiaTürkiyeUkrainesKosovo?

On 3 EU lists (BE, NL, SE): the maker has had the model certified and 3 grid operators accept it. Nothing is checked in these countries themselves: where there is no list the grid operator reads the maker's certificate for that country — ask the maker or installer for it; where a list exists that GridFit has not read, check the model there.

Other procedure: over the type-A limit (1)

Italy

Above the type-A ceiling (11.08 kW in Italy): type B, a procedure of its own — conformity per installation, not a certificate per model.

Unknown: not confirmed (2)

Bulgaria?Georgias

Whether a list or a rule applies is not confirmed yet.

s = from search results, ? = unverified; without a mark the country page was opened. The state per country comes from the EU+ grid-connection table; each country page says more.

List by list

SE — Sweden

List
Rikta Rätt — växelriktare för solceller (dated 2026-10-23)
Status
✓ listed
As written
Fimer · PVS-12.5-TL-SX
Running no.
474
Firmware
?2121A (SWEDEN)
Date
2021-11-19 (reviewed)
Match
exact · seen 2026-10-31

Rows are matched by maker and a normalised model code; the “as written” line shows exactly what each list says. Check the list itself, and your grid operator, before you install.

Local control with Home Assistant and evcc

Checked 2026-10-31.

brand route, model unconfirmed No integration or template names this code. Fimer has 2 families with a local route; whether this model belongs to one of them is not confirmed:

Know which family it belongs to? Fix the row: the family's model-code pattern then claims it.

Wrong match or a newer list? Fix the row

What changed in the lists